Sizes 30 and 40, version NR & Size 50, version NR
- Fuels : HFO, Natural gas, LPG.
- Stated oil throughputs are based on a calorific value of 11.24 kWh/kg for HFO.
- Plotted operational ranges represent maximal values measured on idealised flame tubes in accordance with EN 676 and EN 267.
- Stated ratings are based on an air temperature of 20 °C and an installation altitude of 500 m above sea level.
- For installations at higher altitudes, a reduction in capacity of 1 % per 100 m above sea level should be taken into account.
- Voltages and frequencies: The burners are equipped as standard for three-phase alternating current, 400 V, 3 ~, 50 Hz. Other voltages and frequencies are available on application (no additional cost).
- Standard burner motor: Insulation Class F, IP 55 protection, IE3 efficiency.
Sizes 60 and 70, version NR
- Fuels : Light oil, HFO, Natural gas, LPG.
- Stated oil throughputs are based on a calorific value of 11.91 kWh/kg for light oil and 11.24 kWh/kg for HFO.
- Plotted operational ranges represent maximal values measured on idealised flame tubes in accordance with EN 267.
- Stated ratings are based on an air temperature of 20 °C and an installation altitude of 500 m above sea level.
- For installations at higher altitudes, a reduction in capacity of 1 % per 100 m above sea level should be taken into account.
- Voltages and frequencies: The burners are equipped as standard for three-phase alternating current, 400 V, 3 ~, 50 Hz. Other voltages and frequencies are available on application (no additional cost).
- Standard burner motor: Insulation Class F, IP 55 protection, IE3 efficiency.
Size 70, version NR
- Fuels : Light oil, HFO, Natural gas, LPG.
- Stated oil throughputs are based on a calorific value of 11.91 kWh/kg for light oil and 11.24 kWh/kg for HFO.
- Plotted operational ranges represent maximal values measured on idealised flame tubes in accordance with EN 267.
- Stated ratings are based on an air temperature of 20 °C and an installation at sea level.
- For installations at higher altitudes, a reduction in capacity of 1 % per 100 m above sea level should be taken into account.
- Voltages and frequencies: The burners are equipped as standard for three-phase alternating current, 400 V, 3 ~, 50 Hz. Other voltages and frequencies are available on application (no additional cost).
- Standard burner motor: Insulation Class F, IP 55 protection, IE3 efficiency at 50/60 Hz (no IE classification at 55 Hz).
Size 50, version 1LN & Size 70, version 1LN
- Fuels: Light oil, Natural gas, LPG.
- Stated oil throughputs are based on a calorific value of 11.91 kWh/kg for light oil.
- Plotted operational ranges represent maximal values measured on idealised flame tubes in accordance with EN 676 and EN 267.
- Stated ratings are based on an air temperature of 20 °C and an installation at sea level.
- For installations at higher altitudes, a reduction in capacity of 1 % per 100 m above sea level should be taken into account.
- Voltages and frequencies: The burners are equipped as standard for three-phase alternating current, 400 V, 3 ~, 50 Hz. Other voltages and frequencies are available on application (no additional cost).
- Standard burner motor: Insulation Class F, IP 55 protection, IE3 efficiency.
Reviews