Compact and powerful:
The WKmono 80 is a combination of monobloc and duobloc burner. It retains the compact and service-friendly design, and uses the existing modular construction system of the duobloc WK burner series.
Digital:
- Digital combustion management means optimal combustion figures, continuously reproducible setpoints, and ease of use;
- Simple operation;
- Measures for saving energy and increasing safety and reliability;
- Electronic compound regulation;
- Variable speed drive;
- O2 trim;
- Combined CO/O2 control;
- CO monitoring;
- Flexible communications: Compatible with building management systems;
Specifications:
- Fuels : Natural gas, LPGk, Light oil (35 s gas oil), 10 % biodiesel blends (B10)
Application:
EN 267 and EN 676-approved Weishaupt WKmono 80 burners are suitable for:
- Hot-water plant;
- Steam boilers and high-pressure hot-water plant;
- Intermittent and continuous operation;
- Installation on air heaters;
- Permissible ambient conditions;
- Ambient temperature during operation : -10 to +40 °C (oil/dual-fuel burners) -15 to +40 °C (gas burners);
- Humidity: max. 80 % relative humidty, no condensation;
- Suitable for operation indoors only;
- For plant in unheated areas, certain further measures may be required (please enquire);
Certification:
- The burners are tested by an independent body and conform to the following standards and EU directives:
- Machinery Directive 2006/42/EC;
- Pressure Equipment Directive, 97/23/EC 2014/68/EU (effective 09.07.2016);
- Gas Appliance Directive, 2009/142/EC – EN 676 and EN 267;
- Low Voltage Directive 2006/95/EC 2014/35/EU (effective 20.04.2016) – EN 60335-1, -2, -2-102;
- Electromagnetic Compatibility Directive 2004/108/EC 2014/30/EU (effective 19.04.2016) – EN 61000-6-2, -6-4;
- The burners are marked with a – CE mark – CE Prod. ID No. per 2009/142/EC – ID number of the monitoring body;
Regulation:
- Weishaupt WKmono 80 burners are suitable for sliding-two-stage or modulating operation, depending on the type of capacity regulation;
- NR version: Gas and dual-fuel burners with an advanced-design mixing assembly for installations with Class 2 (oil-side) and Class 3 (gas-side) NOx emission requirements;
- 3LN version: Ultra-Low-NOx gas, oil, and dual-fuel burners with multiflam® mixing assemblies for installations with extremely low NOx emission limits (suitable for three-pass and through-pass boilers only). The burners’ extremely low NOx emissions are achieved using a special fuel distribution system. 3LN-version burners are suitable for light oil, natural gas, and LPG, and meet Class 3 NOx requirements;